26 August, 1999
Baumfolder Corporation 1660 Campbell Rd., P.O. Box 728 Sidney, OH USA 45365-0728
Phone: 937-492-1281 or 800-543-6107 Fax: 937-492-7280
2020 Static Eliminator Installation
There are (2) Static bars (1) Power Pack and a mounting kit included with the Static Eliminator.
One bar is to be mounted at the entry side of the fold rollers and the other at the exit side.
The cables on the bars are inserted into the connections on the main power pack.
The bars are to be mounted approximately no greater than 1” above the paper.
The hardware kit consists of universal mounting brackets that must be bent to fit the folder. The universal
bracket kit is used because there are so many different folders in the market. Note that there are different
“C” brackets for the tiebars. This is also due to the wide variety of folders that this accessory is used on.
Static Eliminator Bar Mounted on Entry Side of Baumfolder 2020 Folder
Static Eliminator Bar Mounted on Exit End of Baumfolder 2020 Folder